Fixing and finding

[Jump to remediation plan](#remediation)

CVE ID

# CVE-2026-110936

Published 2026-10-15

Updated last month

Vendor/s

Siemens

Product/s

Software Center

Version/s

\* > 4.0.9.8

KEV Status

Active Exploitation

Listed in CISA's Known Exploited Vulnerabilities catalog. Active exploitation observed in the wild.

CVSS Score (v3.1)

6.7

/ 10

Medium

Severity Details

Base score

6.7 Medium

Attack vector

Local

Attack complexity

Low

Privileges required

High

User interaction

None

Scope

Unchanged

Confidentiality

High

Integrity

High

Availability

High

Table of Contents

[Description ](#description)[Why this matters ](#why-this-matters)[CPE ](#cpe)[Related weakness (CWE) ](#cwe)[Remediation plan ](#remediation)[Detection Guidance ](#detection-guidance)[References ](#references)[Sources](#sources)

[Description ](#description)[Why this matters ](#why-this-matters)[CPE ](#cpe)[Related weakness (CWE) ](#cwe)[Remediation plan ](#remediation)[Detection Guidance ](#detection-guidance)[References ](#references)[Sources](#sources)

## Description

Siemens Software Center versions before V4.0.9.8 are vulnerable to DLL hijacking, allowing local code execution. Patch immediately as this is KEV-listed.

## Why this matters

"CVE-2026-110936 is a significant security risk for industrial environments using Siemens Software Center. Despite its CVSS score of 6.7, its inclusion in CISA’s Known Exploited Vulnerabilities (KEV) catalog indicates active real-world exploitation. The flaw allows an authenticated local attacker to perform DLL hijacking by placing a malicious file in an uncontrolled search path, leading to arbitrary code execution with the application's elevated privileges. Security teams must prioritize this update because it bridges the gap between local access and full system compromise, potentially serving as a pivot point for more complex attacks within sensitive OT networks."

## CPE

Siemens

| Product          | Version Start | Version End (excl.) | Status     |
| ---------------- | ------------- | ------------------- | ---------- |
| software\_center | \*            | 4.0.9.8             | vulnerable |

## Related weakness (CWE)

CWE-427

## Remediation plan

1

### Apply official patches

Siemens has released an update to address this uncontrolled search path vulnerability. Administrators should download and install the latest version of Siemens Software Center directly from the official Siemens product portal or via the integrated update mechanism.

2

### Update affected systems

Ensure all installations of Siemens Software Center are updated to version 4.0.9.8 or higher. Audit your environment for any legacy versions (all versions prior to V4.0.9.8) and decommission or update them immediately to mitigate the risk of DLL hijacking.

3

### Restrict access

Limit local access to systems running Siemens Software Center. Enforce the principle of least privilege (PoLP) and ensure that standard users do not have write permissions to the application's installation directories or other folders included in the system's DLL search path.

4

### Monitor for exploitation

Use endpoint detection and response (EDR) tools to monitor for suspicious DLL loading events. Specifically, look for unsigned or unexpected DLL files being loaded by the Siemens Software Center process from non-standard or user-writable directories.

## Detection Guidance

"Detection should focus on identifying unauthorized file creation in application directories. Monitor for the creation of .dll files in Siemens Software Center folders by non-administrative users. Review Windows Event Logs for Event ID 7045 or Sysmon Event ID 7 (Image Loaded) where the ImageLoaded path does not match the expected installation path. Prioritize host-based integrity monitoring as the local attack vector bypasses most network-level security controls."

## References

[https://cert-portal.siemens.com/productcert/html/ssa-580366.html Patch Vendor Advisory ](https://cert-portal.siemens.com/productcert/html/ssa-580366.html)[https://productcert.siemens.com/news/2026/10/19/active-exploitation-of-cve-2026-110936-in-siemens-software-center/ Patch Vendor Advisory ](https://productcert.siemens.com/news/2026/10/19/active-exploitation-of-cve-2026-110936-in-siemens-software-center/)[https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field\_cve=CVE-2026-110936 US Government Resource](https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-110936)

## Sources

NIST National Vulnerability Database (NVD)

CISA Known Exploited Vulnerabilities (KEV)

Experience superior visibility and a simpler approach to cyber risk management

[Get a demo](https://www.upguard.com/contact-sales)

[Free trial](https://www.upguard.com/demo)