Fixing and finding
Jump to remediation plan
CVE ID

CVE-2026-83549

Published 2026-09-01
Updated 16 days ago
Vendor/s
SonicWall
Product/s
SMA1000 Appliances
Version/s
* > 12.4.3-03526
KEV Status
Active Exploitation
Listed in CISA's Known Exploited Vulnerabilities catalog. Active exploitation observed in the wild.
CVSS Score (v3.1)
7.8
/ 10
High
Severity Details
Base score
7.8 High
Attack vector
Local
Attack complexity
Low
Privileges required
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Description

CVE-2026-83549 is a high-severity RCE vulnerability in SonicWall SMA1000 appliances. Actively exploited; update firmware to prevent command injection.

CPE

SonicWall logo
SonicWall
Product Version Start Version End (excl.) Status
sma8200v * 12.4.3-03526 vulnerable
sma8200v 12.5.0 12.5.0-02952 vulnerable
sma8200v - - unaffected
sma6210_firmware * 12.4.3-03526 vulnerable
sma6210_firmware 12.5.0 12.5.0-02952 vulnerable
sma6210 - - unaffected
sma7210_firmware * 12.4.3-03526 vulnerable
sma7210_firmware 12.5.0 12.5.0-02952 vulnerable
sma7210 - - unaffected

Related weakness (CWE)

CWE-78

Remediation plan

1

Apply official patches

Immediately download and install the security patches provided by SonicWall for the SMA1000 series. Refer to SonicWall advisory SNWLID-2026-0016 for specific patch instructions for SMA 6210, 7210, and 8200v platforms.

2

Update affected systems

Ensure all SMA1000 appliances are updated to firmware versions 12.4.3-03526 or 12.5.0-02952 and above. Verify that no legacy or unpatched virtual appliances (SMA 8200v) remain active in the environment.

3

Restrict access

Limit access to the Appliance Management Console (AMC) to authorized administrative personnel only via a management VLAN or VPN. Enforce strict Multi-Factor Authentication (MFA) for all administrative accounts to prevent unauthorized access.

4

Monitor for exploitation

Review system logs for unusual shell command activity or unauthorized changes to the appliance configuration. Follow CISA’s Forensics Triage Requirements to scan for indicators of compromise and ensure no persistent backdoors were established.

Detection Guidance

"Detection should focus on monitoring the SonicWall Appliance Management Console (AMC) for anomalous activity. Audit logs for the execution of unexpected system commands or the presence of shell metacharacters in administrative inputs. Security teams should also inspect network traffic for unauthorized outbound connections originating from the SMA appliance, which could indicate a reverse shell. Use endpoint detection tools to flag suspicious child processes spawned by the web server process on the appliance."

References

Sources

NIST National Vulnerability Database (NVD)
CISA Known Exploited Vulnerabilities (KEV)

Experience superior visibility and a simpler approach to cyber risk management