Siemens Software Center versions before V4.0.9.8 are vulnerable to DLL hijacking, allowing local code execution. Patch immediately as this is KEV-listed.
| Product | Version Start | Version End (excl.) | Status |
|---|---|---|---|
| software_center | * | 4.0.9.8 | vulnerable |
Siemens has released an update to address this uncontrolled search path vulnerability. Administrators should download and install the latest version of Siemens Software Center directly from the official Siemens product portal or via the integrated update mechanism.
Ensure all installations of Siemens Software Center are updated to version 4.0.9.8 or higher. Audit your environment for any legacy versions (all versions prior to V4.0.9.8) and decommission or update them immediately to mitigate the risk of DLL hijacking.
Limit local access to systems running Siemens Software Center. Enforce the principle of least privilege (PoLP) and ensure that standard users do not have write permissions to the application's installation directories or other folders included in the system's DLL search path.
Use endpoint detection and response (EDR) tools to monitor for suspicious DLL loading events. Specifically, look for unsigned or unexpected DLL files being loaded by the Siemens Software Center process from non-standard or user-writable directories.
"Detection should focus on identifying unauthorized file creation in application directories. Monitor for the creation of .dll files in Siemens Software Center folders by non-administrative users. Review Windows Event Logs for Event ID 7045 or Sysmon Event ID 7 (Image Loaded) where the ImageLoaded path does not match the expected installation path. Prioritize host-based integrity monitoring as the local attack vector bypasses most network-level security controls."
Experience superior visibility and a simpler approach to cyber risk management